For instance, this reduces cable dimensions substantially. If you continue, you will be logged in and forwarded to your default danfoss store. Installation, startup and maintenance should be performed only by qualified personnel. Page 84 6000 hvac series electrical installation, power cables ip 00 and nema 1 ip 20 vlt 60426062, 200240 v ip 54 vlt 60426062, 200240 v compact ip 54 vlt 61026122, 380460 v mg. The vlt 6000 frequency converter is delivered for installation and setup with the required application parameters already programmed at the factory. Installation, operation and maintenance manual vlt 6000 series adjustable frequency drive. The operating instructions are intended for use by qualified personnel. Inverter danfoss, lesson 08, vlt 5000 600 800 ip21 control and programming duration. Contents introduction to hvac installation vlt 6000 hvac series. A vlt 6000 hvac comes with operating instructions as well as quick setup guide. The motor may start without warning during operation and programming of the parameters. Vlt is a registered danfoss trademark5 general the specific installation instructions may vary depending upon the model of vlt 6000 series being installed. The wellstructured menu system ensures fast commissioning and easy access to. Guideline inverter scroll compressors vzh028035044.
Page 63 6000 hvac series electrical installation, power cables ip 00 and nema 1 ip 20 vlt 60426062, 200240 v ip 54 vlt 60426062, 200240 v compact ip 54 vlt 61026122, 380460 v mg. Vlt 60166072, 525600 v 200 installation on a plane, vertical surface no spacers vlt 60426062, 200240 v 225 vlt 61026402, 525600 v 225 vlt 61526352, 380460 v 225 installation on a plane, vertical surface no spacers ip 54 filter mats must be changed when they are dirty. This number can be found on the red nameplate on the outside left side of the drive. Choice of frequency converter the frequency converter should be chosen on the basis of the given motor current at maximum load on the system. The vlt6000 was danfosss leading hvac drive from 1996 2008. Read and follow the operating instructions in order to use the frequency converter safely and professionally, and pay.
It only briefly touches on the basics of the lonworks protocol whenever it is necessary for gaining an understanding of the lonworks profile for drives and the lonworks option card for the frequency. Danfoss vlt 6000 hvac series design manual pdf download. View and download danfoss vlt 6000 installation manual online. Find new and reconditioned vlt 6000 danfoss inverter drives at eu automation au. Jun, 2014 vlt 5000 series non ul compliance if ulcul is not to be complied with, we recommend the above mentioned fuses or. The danfoss vlt 6000 hvac, dedicated to hvac applications, provides unsurpassed. Vlt series 3000 instruction manual 175r5162 document version 5. Vlt 6000 hvac and vlt 8000 aqua operating instructions software version. The specific installation instructions may vary depending upon the model of vlt 6000 series being installed. Touching the electrical parts, even when the ac line has been disconnected. The vlt 6000 is in the inactive phase and has reached the end of its lifecycle.
This section shows you how to carry out correct mechanical installation of a vlt 6000 hvac. If you continue, you will be loggedout of your danfoss store and directed to the store you have selected. Introduction vlt hvac drive operating instructions mg. Introduction to hvac 4 software version 4 safety regulations 5 warning against unintended start 5 introduction to operating instructions 8 available literature 9 vlt 6000 advantages in a hvac installation 9 control principle 10 aeo automatic energy optimization 11 example of application speed control of fan in ventilation system 12 example. Vrvii cooling only specification smc new type singlestage dc ac control 19. Pdf installation, operation and maintenance manual vlt 6000. Connect the screen from the control cables to terminal 61 ground. Vlt 50015027 200240 v type gg vlt 50325052 200240 v type gr vlt 50015062 380500 v type gg vlt 50725102 380500 v type gr vlt 51225302 380500 v type gg vlt 53525552 380500 v type gr vlt 50015062 525600 v type gg not. This range has now been replaced by the fc102 hvac drive. To determine software version refer to parameter 603, name plate. Danfoss vlt 6000 series operating instructions manual pdf. Follow this manual and local and national safety codes.
It is a small drive with maximum strength and reliability. When indias leading drug maker cipla decided to build a world class drug manufacturing plant at goa, it chose the danfoss vlt 6000 hvac drives to control around 350 ahus and 20 pumps to maintain inside conditions and differential pressure in the manufacturing areas. Vlt 50015027 200240 v type gg vlt 50325052 200240 v type gr vlt 50015062 380500 v type gg vlt 50725102 380500 v type gr vlt 51225302 380500 v type gg vlt 53525552 380500 v type gr vlt 50015062 525600 v. The vlt 6000 hvac complies with iec 632 and 634 as well as vde 0160 as to harmonic distortion. It is strongly recommended that all electrical work conform to the national electrical code nec and all local regulations. References installation, operation and maintenance manual for the vlt 6000 frequency converter, danfoss graham document 23610800. Installation, operation and maintenance manual vlt 6000 series adjustable frequency drive 1201 2 vlt is a registered danfoss trademark. Nov 06, 2014 learn how to start up your danfoss vlt automationdrive using the award winning easytouse local control panel lcp. Danfoss 176f1405 spare pca control board 6000 vlt 5000 series. This manual is intended for use along with the danfoss operating instructions manual for the vlt 5000 6000 8000. Operating instructions, mct 10 setup, modbus rtu instructions, vlt drawings, etc vlt compressor drives literatures application uidelines. View and download danfoss vlt 6000 instruction manual online. Danfoss vlt frequency converters are able to fulfil many different. Danfoss vlt micro drive fc 51 range the vlt micro drive is a general purpose drive that can control ac motors up to 22.
Rohs compliant the vlt micro drive is manufactured with respect for the environment, and it complies with the rohs directive. Danfoss 6000 manual tricia joy programming the vlt 6000. The danfoss vlt 6000 hvac provides unsurpassed performance, energy. It only briefly touches on the basics of the profibus protocol. Learn how to start up your danfoss vlt automationdrive using the award winning easytouse local control panel lcp. If ul cul is to be complied with, cable with temperature class 75oc must be used vlt 5072 5500 380 500 v, vlt 5032 5052 200 240 v, vlt 5075 5250 525 600 v. Danfoss vlt automationdrive fc 302 official distributor. Danfoss vlt6000 inverter hvac drives cse distributors. Installation, operation and maintenance manual tecdriver. The software version can be seen from parameter 624. In addition, the section has a description of how you ensure that the. Vlt6000 obsolete hvac drives danfoss distributor for.
Installation, operation and maintenance manual vlt 6000. Danfoss offers an extensive portfolio of lowvoltage drives and can help you select the optimal replacement drive for your application. Vlt 6000 hvac installation dmm comments bookstyle vlt 60026005, 200240 v 100 vlt 60026011, 380460 v 100 installation on a plane, vertical surface no spacers. Get the best deals on danfoss general purpose industrial ac drives when you shop the largest online selection at. This manual should be read thoroughly before operating, servicing or initializing the drives.
Danfoss v 2800 series general purpose inverters distributors. Danfoss vlt 6000 manuals and user guides, controller. This guide can be used with all vlt hvac drive frequency converters with software version 3. Introduction to hvac 4 software version 4 safety regulations 5 warning against unintended start 5 introduction to operating instructions 8 available literature 9 vlt 6000 advantages in a hvac installation 9 control principle 10 aeo automatic energy optimization 11 example of application speed control of fan in ventilation system 12 example of application. The danfoss vlt 6000 hvac provides unsurpassed performance, energy savings and improved control of hvac systems.
Connectors are for use of both copper and aluminium cables, unless other is specified. These user guides are clearlybuilt to give stepbystep information about how you ought to go ahead in operating certain. Vlt 4000 vt line supply 3 x 200 240 v according to international requirements vlt type 4006 4008 4011 output current ivlt,n a 16. Activate the stop key on the vlt keypad when changing data. The software version number can be seen from parameter 624. When this occurs, the model can be identified by a vlt type 6xxx number. For further reduction in the harmonic distortion, danfoss offers external passive 5% and 10% current distortion filters ahf 005010. Improper installation of the motor or the afd may cause equipment failure, serious injury or death. Automatic bypass controls danfoss when mads clausen founded danfoss in his parents farmhouse in nordborg, automatic bypass controls. The actual software version number can be read from par. User manuals, guides and specifications for your danfoss vlt 6000 controller. View online operating instructions manual for danfoss vlt 6000 controller or simply click download button to examine the danfoss vlt 6000 guidelines offline on your desktop or laptop computer. Vlt 2800 adjustable frequency drives allow sidebyside installation on a wall in any position as the units do not require ventilation on the side. Get the best deals on danfoss general purpose industrial ac drives when you shop the.
You have been signed out due to inactivity the last 120 minutes. Rotating shafts and electrical equipment can be hazardous. It only briefly touches on the basics of the profibus protocol whenever it is necessary for gaining an understanding of the profidrive implementation of the profibus. Many products that you buy can be obtained using instruction manuals. Vlt 6000 hvac is available for two mains voltage ranges. Guideline inverter scroll compressors vzh028035044 single. Vlt is a registered danfoss trademark7 general the specific installation instructions may vary depending upon the model of vlt 6000 series being installed. Make offer danfoss vlt 2800 195n1029 inverter drive. When a vlt 6000 hvac is supplied, it is accompanied by operating instructions and a quick setup guide. The software version number can be seen from parameter 1543 software version. The drive conversion wizard in the mct software, which is free to download from danfoss, will automatically convert your vlt5000 or 6000 parameters to the latest generation fc 302 drives at a click of a button. Danfoss vlt 5000 inverter drives ip20ip54 cse distributors. Operating instructions manual, installation manual, instruction manual, manual.
1433 830 852 1403 349 15 616 1655 585 404 1223 1418 1178 1082 1124 625 1621 702 1310 383 1505 810 70 545 718 1127 1213 841 783 1249 450 964 306 892 367 224 1038 1203 1247 535 504 365